Badger Meter WCM255131 Admix Four Unit Controller
Enclosure Type:
Console type, NEMA 12, 13
Enclosure Dimensions:
14.00" W × 10.75" H × 13.50" D (356 mm W × 273 mm H × 343 mm D)
Switches:
4-digit pushwheel (Batch Preset)
3-position toggle (Admix Unit Select)
2-position toggle (Discharge Hold)
Momentary pushbuttons (Start, Manual Fill, Manual Discharge)
Display:
Four 7-segment red LED digits
Input Power Supply:
Standard 120V AC±10%, 50/60 Hz, 1 Amp
Optional 220/240V AC±10%, 50/60 Hz, 0.5 Amp
Count Input:
Standard
-I/O Module
-120V AC pulse 8 mA max.
-20 ms Turn On/Off
Optional
-I/O Module
-2.5-28V DC pulse 30 mA max.
-1 ms Turn On/1.5 ms Turn Off
Probe Input:
• Probe inputs must come from a probe amplifier, which provides a dry contact closure when the probe is covered.
• The AC-154 Probe Connections cannot be connected directly to the probe.
Standard
-I/O Module
-120V AC 8 mA max.
-Input when probe is covered
Optional
-I/O Module
-2.5-28V DC 30 mA max.
-Input when probe is covered
Solenoid Valve Outputs:
Standard
-I/O Module;
-Fused output 120V AC 3.5 Amp max.
Optional
-I/O Module;
-Fused output 220/240V AC or 12-24V DC
Operating Temperature:
32-130° F (0-54° C)
Humidity:
100% non-condensing