Badger Meter 255317-0001 Concrete Truck Meter
MEASURE RITE MR1-B (Battery Operated) Concrete Truck Meter - 3/4"
Pressure Rating: 400 psig (28 bar) (Class 250),
225 psig at 180° F (15 bar at 82° C)
Max Ambient Temperature: 140° F (60° C)
Accuracy: ±1% or better (within flow range) when properly calibrated
Meter Size & Flow Range:
3/4" NPT - 5-30 gpm (19-114 lpm)
MATERIALS:
Meter: Body Bronze
Impeller: 316 SST
Shaft: Tungsten Carbide
Bearings: Torlon (high performance polymer)
Electronics Housing: Coated Aluminum
Window: Tempered Glass
The MEASURE RITE MR1-B battery operated Truck and Slump Rack Meter permits accurate tracking of all Temper and Slump-Rack water usage without the need for an external power supply.
The ladder platform area is the ideal mounting location for reardischarge truck meter applications, just upstream (and in line with) the water manifold. The meter may also be mounted securely at the slump and washout racks. Verify that any movement of the platform will not cause the meter to contact the barrel or other components.
The MEASURE RITE Volumetric Truck Meter will allow the user to accurately measure the amount of add water on the truck or at the slump rack.
Features:
• Air slug tolerant
• Highly rugged and durable
• Compact and user friendly
• Easy to install
• Easy to calibrate
• Single button operation
• Powered by two internal lithium batteries (handle according to state/federal guidelines)
• On-Off switch to conserve power and extend battery life Options
Options:
• Mounting bracket 3/4" and 1" units
• Ball valve (mount 6" downstream of meter)
• Upstream strainer (60 mesh recommended at least 12" upstream of valve)
• Vertical Front Panel Rotation
• Tees, along with a variety of bearings and seals materials (Consult Factory)
Power:
• Internal batteries, no external wires.
• The unit contains two (2) C-size lithium batteries.
• The batteries are potted into the housing, which is replaceable only by the factory.
• If used (switch-on) for approximately 8-10 hours/day, battery life expectancy is at least 5 years.
• Units containing lithium batteries should be handled according to state, federal and local regulations.
Uses:
• Metering Site Add-Water for Rear Discharge Mixers
• Metering Site Add-Water for Front Discharge Mixers
• Metering On Mixers with Fleet Management Systems
• Metering Temper and Slump-Rack Water
• Tracking Temper and Slump-Rack Water at the Control House

Ask one of our experts
Technical Information
Pressure Rating: 400 psig (28 bar) (Class 250),
225 psig at 180? F (15 bar at 82? C)
Max Ambient Temperature: 140? F (60? C)
Accuracy: ?1% or better (within flow range) when properly calibrated
Meter Size & Flow Range:
3/4" NPT - 5?30 gpm (19?114 lpm)
MATERIALS:
Meter: Body Bronze
Impeller: 316 SST
Shaft: Tungsten Carbide
Bearings: Torlon (high performance polymer)
Electronics Housing: Coated Aluminum
Window: Tempered Glass