Aftermarket Replacement for

Badger Meter 255131 Admix Four Unit Controller

Price

$11,400.12

QTY


This item is NOT eligible for returns or cancellations
Part Number: 255131

Enclosure Type:
Console type, NEMA 12, 13

Enclosure Dimensions:
14.00" W × 10.75" H × 13.50" D (356 mm W × 273 mm H × 343 mm D)

Switches:
4-digit pushwheel (Batch Preset)
3-position toggle (Admix Unit Select)
2-position toggle (Discharge Hold)
Momentary pushbuttons (Start, Manual Fill, Manual Discharge)

Display:
Four 7-segment red LED digits

Input Power Supply:
Standard 120V AC±10%, 50/60 Hz, 1 Amp
Optional 220/240V AC±10%, 50/60 Hz, 0.5 Amp

Count Input:
Standard
-I/O Module
-120V AC pulse 8 mA max.
-20 ms Turn On/Off
Optional
-I/O Module
-2.5-28V DC pulse 30 mA max.
-1 ms Turn On/1.5 ms Turn Off

Probe Input:
• Probe inputs must come from a probe amplifier, which provides a dry contact closure when the probe is covered.
• The AC-154 Probe Connections cannot be connected directly to the probe.
Standard
-I/O Module
-120V AC 8 mA max.
-Input when probe is covered
Optional
-I/O Module
-2.5-28V DC 30 mA max.
-Input when probe is covered

Solenoid Valve Outputs:
Standard
-I/O Module;
-Fused output 120V AC 3.5 Amp max.
Optional
-I/O Module;
-Fused output 220/240V AC or 12-24V DC

Operating Temperature:
32-130° F (0-54° C)

Humidity:
100% non-condensing

The Model AC'154 controller has been specifically designed to operate up to four concrete admixture dispenser systems. Solid-state circuitry and microprocessor technology give the AC'154 superior operating characteristics. The AC-154 allows Manual or Automatic modes of operation with the ability to batch concrete admixtures in total ounces, ounces per 100 wt of cement, or ounces per cubic yard. During the batching process, the AC-154 provides visual LED
indication of the zero point, fill, fill complete, discharge, and overfill. In addition to providing timers to empty discharge lines and sequence discharging of admixtures, the AC-154 has a Discharge Hold function and four safety features. The safety features include overfill protection, no-start on zero indication (to prevent double batching), no-flow/meter fail-safe, and shutoff on batch error. The AC-154 is also designed to accept a count input from Badger Meter® Model PM-5 and CT reed switch transmitters and Model PFT-1E electronic scalable transmitter. Zero and overfill inputs can be accepted from Model DP-10 probe Amplifier or any probe Amplifier that provides a dry contact closure when the probe is covered.

OPERATION
Solid-state circuitry and microprocessor technology allow you to operate the AC-154 in a Manual or Automatic mode by selecting a switch on the front panel. In the Automatic mode, you set a batch size by using the pushwheel switches on the front panel. You can set the batch size in total ounces, ounces per 100 wt cement, or ounces per cubic yard. Use the four toggle switches to select the admix dispensers to be operated. To dispense admixture automatically, press and release the Start button. The digital display zeroes out and begins counting up to the preset amount, as the admix dispenser bottle fills. When the preset amount is reached, the AC-154 goes into the discharge cycle. Discharge operation depends on the position of the Discharge Hold switch. When ON, the discharge cycle stops. When OFF, the discharge cycle continues until the material reaches a zero level. In the Manual mode, only one admix dispenser can be operated at a time. When a dispenser is selected (by using one of the four toggle switches), press and hold down the Manual Fill button to fill the admix dispenser bottle. As the bottle fills, the LED displays the amount. When the desired amount is reached, release the Manual Fill button to stop the fill cycle. To discharge manually, press and hold the Manual Discharge button. The material discharges until a zero level is reached. When the discharge stops, release the Manual Discharge button.

FEATURES
• Controls up to 4 admixtures
• Batch preset in 1 of 3 modes
• Measures total ounces, ounces per cwt or ounces per cubic yard
• Remote-start fill and remote-start discharge
• Automatic or manual operation
• Sequence discharging
• Line empty capability
• Can be operated in U.S. or metric standards
• Accepts 110V or 220V primary power
• Optional output voltage capability
• Opto-isolated inputs and outputs
• Filter network on primary power

OPTIONS
• 1

Question
Do you have a question about this product?
Ask one of our experts
Your Name
Enter your email or phone number for us to contact you about this product.
Please note that we cannot guarantee fitment without a part number. Please submit a full mailing address and phone number when submitting a quote request.

Technical Information
Enclosure Type:
Console type, NEMA 12, 13

Enclosure Dimensions:
14.00" W ? 10.75" H ? 13.50" D (356 mm W ? 273 mm H ? 343 mm D)

Switches:
4-digit pushwheel (Batch Preset)
3-position toggle (Admix Unit Select)
2-position toggle (Discharge Hold)
Momentary pushbuttons (Start, Manual Fill, Manual Discharge)

Display:
Four 7-segment red LED digits

Input Power Supply:
Standard 120V AC ?10%, 50/60 Hz, 1 Amp
Optional 220/240V AC ?10%, 50/60 Hz, 0.5 Amp

Count Input:
Standard
-I/O Module
-120V AC pulse 8 mA max.
-20 ms Turn On/Off
Optional
-I/O Module
-2.5?28V DC pulse 30 mA max.
-1 ms Turn On/1.5 ms Turn Off

Probe Input:
  • Probe inputs must come from a probe amplifier, which provides a dry contact closure when the probe is covered.
  • The AC-154 Probe Connections cannot be connected directly to the probe.
    Standard
    -I/O Module
    -120V AC 8 mA max.
    -Input when probe is covered
    Optional
    -I/O Module
    -2.5?28V DC 30 mA max.
    -Input when probe is covered

    Solenoid Valve Outputs:
    Standard
    -I/O Module;
    -Fused output 120V AC 3.5 Amp max.
    Optional
    -I/O Module;
    -Fused output 220/240V AC or 12?24V DC

    Operating Temperature:
    32?130? F (0?54? C)

    Humidity:
    100% non-condensing